After investigating the existing system, ESSE proposed the technical solution of its FOSS®4+1. After revamping, the new system can meet the prevailing standard and regulations issued by Shandong province in the year 2017 in terms of de-SO2, de-NOx, De-Mercury as well. The existing scrubber tower and sub-product production system has been also utilized to minimize the initial investment on condition that the emission index is in the line of the prevailing standard.

Besides, ESSE also supplied the tailor made services to help customer solve the waste water and solid waste problems.

 

Performance before and after revamping

 

Item

Inlet SO2 mg/Nm3

Outlet SO2 mg/Nm3

Inlet NOx mg/Nm3

Outlet NOx mg/Nm3

Inlet particle
mg/Nm3

Inlet particle
mg/Nm3

Before

1500

30

-

-

100

30

After

1500

100

-

-

100

60

Item

 Power Consumption
Kwh

Water Consumption
t/h

De-Sulphur agent(MgO)
t/h

Crystal Powder Productivity
t/h

Unit Running Cost/ton of sintering ore
CNY/t

Annual Running Cost saving/
10000rmb

After

1036+1445

35

1.25

2.5

5.5

2332

Before

2675

38

1.44

14.3